hirose package:boot R Documentation Failure Time of PET Film Description: The 'hirose' data frame has 44 rows and 3 columns. PET film is used in electrical insulation. In this accelerated life test the failure times for 44 samples in gas insulated transformers. 4 different voltage levels were used. Usage: hirose Format: This data frame contains the following columns: 'volt' The voltage (in kV). 'time' The failure or censoring time in hours. 'cens' The censoring indicator; '1' means right-censored data. Source: The data were obtained from Hirose, H. (1993) Estimation of threshold stress in accelerated life-testing. _IEEE Transactions on Reliability_, *42*, 650-657. References: Davison, A.C. and Hinkley, D.V. (1997) _Bootstrap Methods and Their Application_. Cambridge University Press.